Model | HTD-60W-B | |
Input | Voltage Range | 90 ~ 264 VAC |
Frequency Range | 47 ~ 63 Hz | |
Efficiency | ≥85%@Rated voltage | |
AC Current | 1.6A | |
Inrush Current | Cold start:≤30A@115Vac;≤50A@230Vac | |
Leakage Current | <0.75mA@264Vac | |
Output | Rated Voltage | DC 12V |
Rated Current | 5A | |
Voltage Adjustment Range | DC 12V ~ 15V | |
Current Range | 0~5A | |
Rated Power | 60W | |
Ripple & Noise | ≤120mVpk | |
Voltage Tolerance | ±3% | |
Battery Charging Voltage | 13.8V | |
Battery Charging Current | 0 ~ 0.3A | |
Line Regulation | ≤0.1% | |
Load Regulation | ≤3% | |
Setup,Rise,Hold Up Time | 230Vac Full load:≤3S,≤3S,≥30mS | |
Protection | Over load | 120% ~ 150%@Rated power. Hiccup mode, recovers automatically after fault condition is removed. |
Over Voltage | 120% ~ 130%@Rated voltage. Hiccup mode, recovers automatically after fault condition is removed. | |
Over Current | 120% ~ 150%@Rated current. Hiccup mode, recovers automatically after fault condition is removed. | |
Short Circuit | No damage,Hiccup mode, recovers automatically after fault condition is removed. | |
Battery Protection | Undervoltage protection | |
Environment | Working Temp.,Humidity | Temp.:-10℃ ~ +40℃ ;Humidity:10% ~ 95% RH, Non-condensing |
Storage Temp.,Humidity | Temp.:-20℃ ~ +85℃ ;Humidity:10% ~ 95% RH, Non-condensing | |
Temp.Coefficient | ≤0.05V/℃(0℃ ~ +45℃) | |
Vibration | 10 ~ 500Hz,2G 10min./1cycle, 60min. each along X,Y,Z axes | |
Safety & EMC | Safety Standards | CE:EN/IEC 62368-1;EN/IEC 60950-1 |
Withstand Voltage | IP~OP: ≥3KVac | |
Isolation Resistance | IP~OP: ≥100MΩ@500Vdc,25℃,70% RH | |
EMC | FCC/Part 15 ;EN55032、EN55035;EN/IEC61000 | |
Others | Product Size | 159.5*98*41.9mm |
Packing | 50pcs/carton, 56*39.8*23.1CM | |
Warranty | 2 Years |